Single Channel Electrochemical Workstation Potentiostat Galvanostat for Battery Test


SPECIFICATIONS


CS electrochemical workstation (potentiostat / galvanostat) contains a fast digital function generator, high-speed data acquisition circuitry, a potentiostat and a galvanostat. With high performance in stability and accuracy with advanced hardware and well-functioned software, it is a comprehensive research platform for corrosion, batteries, electrochemical analysis, sensor, life science and environmental chemistry etc.

Applications
(1) Reaction mechanism of Electrosynthesis, electrodeposition (electroplating), anodic oxidation, etc.
(2) Electrochemical analysis and sensor;  
(3) New energy materials (Li-ion battery, solar cell, fuel cell, supercapacitors), advanced functional materials, photoelectronic materials;
(4)Corrosion study of metals in water, concrete and soil etc;
(5) Fast evaluation of corrosion inhibitor, water stabilizer, coating and cathodic protection efficiency.


Specifications

Support 2-, 3- or 4-electrode system

Potential control range: ±10V

Current control range: ±2A

Potential control accuracy: 0.1%×full range±1mV

Current control accuracy: 0.1%×full range

Potential resolution: 10μV (>100Hz),3μV (<10Hz)

Current sensitivity:1pA

Rise time: <1μS (<10mA), <10μS (<2A)

Reference electrode input impedance:1012Ω||20pF

Current range: 2nA~2A, 10 ranges

Compliance voltage: ±21V

Maximum current output: 2A

CV and LSV scan rate : 0.001mV~10,000V/s

CA and CC pulse width: 0.0001~65,000s

Current increment during scan: 1mA@1A/ms

Potential increment during scan: 0.076mV@1V/ms

SWV frequency: 0.001~100 kHz

DPV and NPV pulse width: 0.0001~1000s

AD data acquisition:16bit@1 MHz,20bit@1 kHz

DA Resolution:16bit, setup time:1μs

Minimum potential increment in CV: 0.075mV

IMP frequency: 10μHz~1MHz

Low-pass filters: Covering 8-decade

Potential and current range: Automatic

PC and O/S requirement

 Interface: USB 2.0

Operating System: 

Windows 2000/NT/XP/ win7/win8/win10

Weight / Measurements

Net weight: 6.5kg Gross weight: 10kg

Instrument size: 36.5 x 30.5 x16cm; After package: 52.5 x 37.5x 22.5cm


Electrochemical Impedance Spectroscopy(EIS)

Signal generator

Frequency range:10μHz~1MHz

AC amplitude:1mV~2500mV

DC Bias:-10~+10V

Output impedance:50Ω

Waveform: sine wave, triangular wave and square wave

Wave distortion:<1%

Scanning mode: logarithmic/linear, increase/decrease

Signal analyzer

Integral time:minimum:10ms or the longest time of a cycle

Maximum:106 cycles or 105s

Measurement delay:0~105s

DC offset compensation

Potential automatic compensation range:-10V~+10V

Current compensation range:-1A~+1A

Bandwidth: 8-decade frequency range, automatic and manual setting


Technical advantages

1. Impedance (EIS)
CS potentiostat applies correlation integral algorithm and dual-channel over-sampling technique, and has strong anti-interference ability. It is suitable for EIS measurements of high-impedance system (>109Ω, such as coating, concrete etc.). It can also be used to obtain Mott-Schottky curve and differential capacitance curve. During test, the software can display real-time open circuit potential(OCP) without entering.
Electrochemical Workstation

2. Polarization curve

Polarization curve / Tafel plot can be obtained. The user can set the anodic reversal current (passivation film breakdown current) of the cyclic polarization curve to determine material’s pitting potential and protection potential and evaluate the its susceptibility to intergranular corrosion. The software employs non-linear fitting to analyze polarization curve, and can make fast evaluation of material’s anti-corrosion ability and inhibitors.


3. Voltammetry

It can do the following experiments: Linear Sweep Voltammetry(LSV), Cyclic Voltammetry(CV), Staircase Cyclic Voltammetry(SCV), Square wave voltammetry(SWV), Differential Pulse Voltammetry(DPV), Normal Pulse Voltammetry(NPV), AC voltammetry(ACV), Stripping voltammetry etc. It integrates calculation of peak area, peak current and standard curve analysis.

Electrochemical Workstation

4. Electrochemical Noise
With high-resistance follower and zero-resistance ammeter, it measures the natural potential/current fluctuations in corrosion system. It can be used to study pitting corrosion, galvanic corrosion, crevice corrosion, and stress corrosion cracking etc. Through noise spectrum, we can evaluate the inducement, growth and death of metastable pitting and crack. Based on calculation of noise resistance and pitting index, it can complete localized corrosion monitoring.


5. Full floating measurement

CS workstation uses full-floating working electrode. It can be used for autoclave electrochemical measurements, on-line corrosion monitoring of metallic components under the ground (rebar in concrete, etc.)


6. User-defined methods

CS workstation supports user-defined combination measurements. The user can set cyclic  timing measurements of an electrochemical method or several methods. 
We are able to provide API functions and development examples, which facilitates some users’ requirements for secondary development and self-defined measurements.


Techniques

TOB-CS150

TOB-CS300

TOB-CS310

TOB-CS350

Stable polarization

Open Circuit Potential (OCP)

Potentiostatic (I-T curve)

Galvanostatic

Potentiodynamic(Tafel plot)

Galvanodynamic

Transient polarization

Multi-Potential Steps

Multi-Current Steps

Potential Stair-Step (VSTEP)

Galvanic Stair-Step (ISTEP)

Chrono methods

Chronopotentiometry (CP)


Chronoamperometry (CA)


Chronocoulometry (CC)


Voltammetry

Cyclic Voltammetry (CV)

Linear Sweep Voltammetry (LSV)

Staircase Voltammetry (SCV) #



Square wave voltammetry (SWV) #



Differential Pulse Voltammetry (DPV)#



Normal Pulse Voltammetry (NPV)#



Differential Normal Pulse Voltammetry(DNPV)#



AC voltammetry (ACV) #



2nd Harmonic A.C.Voltammetry (SHACV)



Amperometry

Differential Pulse Amperometry (DPA)




Double Differential Pulse Amperometry (DDPA)




Triple Pulse Amperometry (TPA)




Integrated Pulse Amperometric Detection (IPAD)




EIS

EIS vs Frequency (IMP)



EIS vs Time (IMPT)



EIS vs Potential (IMPE)(Mott-Schottky)



Corrosion test

Electrochemical Potentiokinetic Reactivation(EPR)

Electrochemical Noise(EN)

Zero resistance Ammeter(ZRA)

Battery test

Battery charge and discharge

Galvanostatic charge and discharge(GCD)

Extensions

Data Logger

Electrochemical stripping/deposition


Bulk electrolysis with Coulometry (BE)


Product Display


Electrochemical Workstation

Electrochemical Workstation

Electrochemical Workstation

Electrochemical Workstation


 Email : tob.amy@tobmachine.com

 Skype :amywangbest86

 Whatsapp/Phone number :+86 181 2071 5609

Send a Message

If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

our works
related products
Electrochemical Workstation
Multichannel Potentiostat Galvanostat Electrochemical Workstation
TOB-CS-3 Multichannel potentiostat/ galvanostat/EIS is a versatile instrument offering 8 slots. High current/voltage: Applied potential range ±10V, current ±1A. Comprehensive techniques: Built-in EIS (10μHz~1MHz) is equipped.
Bipotentiostat
2 Channel Bipotentiostat
TOB-CS-2350 bipotentiostat is developed from single channel TOB-CS-350 potentiostat/galvanostat. There are two s ets of built-in potentiostat /galvanostat. The two channels can conduct same or different experiments ind ependently/simultaneously.
Sodium ion Battery Charge and Discharge Machine
Cylindrical Sodium ion Battery Charge and Discharge Machine for 18650S 32138S 32140S
TOB-HF512-3K 5V3A sodium ion battery charge and discharge machine it is suitable for 18650S 1.3Ah, 32138S/10Ah, 32140S /10Ah ,etc. battery chemical formation and grading.
Carbon Cloth
High Electrical Conductivity Carbon Cloth For Supercapacitor
This kind carbon cloth is with high electrolyte absorbent performance, suitable for improve supercapacitor and battery capacity.
China Leading 1100 ℃ dual temperature zones high temperature high pressure furnace Manufacturer
1100 ℃ dual temperature zones high temperature high pressure furnace
1100 ℃ dual temperature zones high temperature high pressure furnace
 Lithium Air Battery Research
Split Test Cell for Lithium Air Battery Research
The EQ-STC-LI-AIR is Split Test Cell for Lithium Air Battery Research. You can control air flow pressure and test various anode and cathode material at easy.
2032 coin cell case
coin cell case cr2032 - 316 stainless steel with gasket
coin cell case cr2032 - 316 stainless steel with gasket
China Leading High - temperature type graphene powder Manufacturer
High - temperature type graphene powder
Graphene powder (high - temperature) SPECIFICATIONS Packing:10g/bag Mode: TOB-G1331   Model Standard value   tap density(g/ml) particle-size analysis purity(%) water(%) ash content(%) Sheet thickness (nm) thermal conductivity(w/m.k) D10/(um) D50/(um) D90/(um) SE1330 0.08~0.1 ≤5 ≤10 ≤20 ≥99 ≤0.5 ≤0.5 ≤10 5300 Performance: (1)Excellent performance of thermal conductivity,  With PC composite prepared insulation materials thermal conductivity  more than 15W/mK,With PA6 composite prepared insulation materials thermal conductivity more than 20W/mK. (2)Pieces of thin, easy to disperse, easy processing. (3)Having the lower percolation threshold  Application: Mainly used in the field of radiating coating, thermal conductivity glue,  conductive plastics, conductive rubber, LED cooling etc. Handling and storage Operators should be trained, strictly abide by the rules. Proposed operators wear appropriate protective clothing,wear suitable chemical protective gloves,  avoid breathing, avoid direct contact with eyes and skin.  and number of fire equipment and emergency treatment equipment. Store in a cool, ventilated and dry place.  Keep the container sealed. Away from fire, heat source.  With the strong oxidation agent separate storage.  Storage area is equipped with the appropriate variety and quantity of fire fighting equipment,  emergency treatment equipment and appropriate container materials. PACKAGE                  Email : tob.amy@tobmachine.com  Skype : amywangbest86  Whatsapp/Phone number : +86 181 2071 5609

leave a message

    If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

Company

top