battery machine and materials solution
Products

Hot Products


Helium Leak Detector
Loading...

Helium Leak Detector for Prismatic Cell Leakage Test

This TOB-HJ-N210 Prismatic Cell Helium Mass Spectrometer Leak Detector is suitable for the leakage detection of prismatic cell. Manual pick and place material, automatic leakage detection and give the test results, OK no alarm, NG alarm.
  • Brand:

    TOB NEW ENERGY
  • item no.:

    TOB-HJ-N210
  • order(moq):

    1set
  • Payment:

    L/C,T/T
  • product origin:

    China
  • shipping port:

    XIAMEN
Product Detail

Helium Leak Detector for Prismatic Cell Leakage Test



SPECIFICATIONS


This TOB-HJ-N210 Prismatic Cell Helium Mass Spectrometer Leak Detector is suitable for the leakage detection of prismatic cell. Manual pick and place material, automatic leakage detection and give the test results, OK no alarm, NG alarm.

The helium inspection tooling is based on the customer's prismatic cell.


Technical characteristics of the equipment

1. Number of inspectable battery 1

2. Minimum detectable leak rate 3 × 10-13Pa -m3/s

3. Leak rate display range 1 × 10-1 -----1 × 10-13Pa -m3/s

4. Start-up time ≤ 100s

5. Response time ≤ 0.3 S

6. Maximum pressure at leak detection port 2000Pa

7. Power requirement AC220V±10%/50Hz

8. Leak rate unit Pa -m3/s, ppm, mbar - l/s, atm.cc/s

9. Display interface Large 7.0-inch touch-screen display, the operating interface is clear and easy to understand.

10. Unqualified leakage rate settings, alarm volume settings, etc., with automatic alarm leakage measurement, sound and screen prompts

11. With serial port RS232 level output

12. Large-capacity memory, can store 10,000 groups of test results

13. USB data output, can be directly written into the U disk test data

14. Input and output points are abundant

15. With a perfect product chain, a variety of options to meet different product testing needs

16. Third-party calibration of standard leakage holes with certificates


Principle

The helium mass spectrometer is a gas tightness testing instrument made of helium as a search gas according to the principle of mass spectrometry. The principle of mass spectrometry is shown in the figure.

The electrons emitted from the filament oscillate back and forth in the ionisation chamber, and collide with the gas in the ionisation chamber and the helium entering the chamber through the leakage holes of the inspected parts to ionise into positive ions, which enter the magnetic field under the action of the accelerating electric field, and then deflect due to the action of the Lorentz force to form an arc-shaped orbit.

The ions of different masses pass through the magnetic field and the receiving slit to the receiving pole and are detected.


Main parts of equipment:

1. Helium mass spectrometry leak detector: testing equipment, including host and mechanical pump two parts.

2. Leak testing tooling: including helium filling mechanism, chamber, shell and so on.

3. Control system: customised control system.

4. Rack: aluminium frame, where the leak detector, control system, leak detection tooling and so on are placed.


Process operation instructions

1) Preparation

Switch on the power switch of the equipment and open the air supply valves of compressed air, nitrogen and helium. When the equipment start-up is complete, adjust the pressure reducing valve pressure to the appropriate value and get ready.

2) Battery placement

Detect the appearance of the battery board flat, no big mistakes, the square battery battery will be placed in the detection of tooling with the shape of the positioning slot, the battery is placed.

3)Start pre-sampling

Press the start button of the leak detector to start the inspection process. The cylinder presses the battery and filling port, at this time, the leakage detection control program receives the start signal and starts the leakage detector's pre-stage pump, when the pressure of the leakage detector port reaches the set value within the set time, the pre-pumping is successful, and enters the next step of the process; if the pressure of the leakage detector port doesn't reach the set value within the set time, it means that the battery isn't well placed, or the battery is placed correctly, but the battery has a big breakage, and at this time, the leakage detector will alarm and prompt the staff. The leak detector will alarm and prompt the staff at this time.

4)Pre-pumping failure

If the pre-sampling fails, the staff can press the stop button to stop the detection, or can be set in the system to stop automatically. After stopping, the staff will check and deal with the situation: if there is damage, the battery is not qualified and will be replaced by a new one; if it is not placed properly, the battery will be placed properly again, and then press the start button to start the testing process.

(5) Evacuation and helium leakage detection

After evacuation, the leak detector continues to evacuate the battery for leakage detection, and the system helium spray valve opens to spray helium 0-3S (helium spray time can be set). At this time, the inside of the square battery is full of helium, when there is a leakage hole in the product, the helium molecules leak into the vacuum cavity through the leakage hole, the leakage detector pumps the vacuum cavity for leakage checking, and passes the test without alarming, but alarms if there is a leakage.

6)Feedback of test result

After the leakage detection is completed, manually press the stop button of the leakage detector (automatic stop can be set), the cylinder rises up, the system opens the blowing valve to blow away the helium residual in the leakage detector base, and at the same time the fan opens to blow away the helium around it, so as to prevent it from influencing the next detection, and then pick up the batteries and classify them into categories for placing.


Test process requirements

Name

Parameters

Tracer gas

Helium

Test Method

Positive pressure method

Working vacuum

<40Pa

Vacuum Leak Detection Interface

KF25

Helium injection method

System controlled automatic helium filling

Helium filling pressure

0-0.3Mpa adjustable

Qualified Leakage Rate

≤5.0×10-7Pa.m3/s

System function

System automatic helium injection, leak detector detection and results

Beats

1ppm

Battery compatibility range

210X175(LxW)


Equipment Accessories List

Name

Descriptions

Qty

Inspection Tooling

Customised

1 Pair

Middle seal solenoid valve

Airtac 4V230C06

2 Pcs

Electric control system

Control of the entire machine movement

1 Set

Workbench

Customised

1 Set

Helium detector main unit


1 Pc

Helium Detector Pre-stage Pump

Leybold D16C

1 Set

Digital pressure switch

Airtac

1 Pc

Solenoid valve

Smc VX2B4AA

3 Set

Cylinder

Airtac

2 Set

Safety grating

Espe

1 Pair

Air handling components

Airtac Duplicates Regulators

3 Pc

Electricity

Industrial control board

1 Pc

Electrical boxes

500*400*200

1 Pc


Working Environment Requirements

Working environment

1)Working temperature: 5~40℃;

1)Humidity: ≤95%R.H;

2)Power supply: AC220V±10% , 50±2 Hz;

3) compressed air: air pressure 0.5MPa-0.8 MPa, oil content ≤ 0.01mg/m3, dust particles diameter ≤ 0.01μm, pressure dew point -40 ℃;

4) Compressed air requirements: Party A installs compressed air pipeline and connects it to the main pipeline in the workshop where the equipment is placed, and the compressed air pipeline is reserved for the air source interface and has a manual ball valve; Party A is responsible for all the air facilities from the equipment air source interface to the ball valve, and Party B will provide the equipment with the location information of the air source interface, including the interface size, pressure, flow rate, and the specific location;

5) Nitrogen: purity (V/V): 99%, outlet pressure ≥ 0.6MPa.

6)Helium: industrial bottled helium (provided by Party A)

Cylinder model: T40L, refer to standard GB/T4844-2011;

Filling pressure: 13.5±0.5MPa;

Helium purity (V/V): 99.99%.

7) Power requirements: Party A reserves the total power socket of the equipment in the workshop where the equipment is placed, and Party B provides the location of the power interface of the equipment, including the size of the interface and power requirements;


Inspected battery requirements:

1) The outer surface and interior of the inspected battery should be free of water, oil, other corrosive liquids and gases, metal shavings and other dust.

(2) The embossment caused by the sealing material after contacting the battery shall not be a reason for Party A to reject the acceptance. If there is a requirement for embossing, it should be stated and verified in advance, and the subsequent promotion of the project should be carried out after meeting the requirements.


Product Display


Helium Leak Detector for Prismatic Cell Leakage Test

Helium Leak Detector for Prismatic Cell Leakage Test

Helium Leak Detector for Prismatic Cell Leakage Test

Helium Leak Detector for Prismatic Cell Leakage Test

Helium Leak Detector for Prismatic Cell Leakage Test

Helium Leak Detector for Prismatic Cell Leakage Test


Explore More Prismatic Cell Equipment



 Email : tob.amy@tobmachine.com

 Skype : amywangbest86

 Whatsapp/Phone number : +86 181 2071 5609

Send a Message

If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

our works
related products
Hot Press Machine
200*200mm Size Hot Press Machine For Battery Cells
This TOB-RY200 hot press machine is a 200*200mm size hot press machine for battery cells.
Film Applicator
180mm Width Film Applicator With Slurry Guiding Plate
The operator sets the blade clearance by adjusting the micrometers. This is excellent tool to make quality film for material research laboratories to make ceramic tape casting, battery electrodes, and various coating at lower cost. Stainless steel knife blade with precision ground edge.
China Leading 1600 ℃ atmosphere chamber furnace Manufacturer
1600 ℃ atmosphere chamber furnace
1600 ℃ atmosphere chamber furnace
China Leading CNC Belling Machine For Super Capacitor Shell Manufacturer
CNC Belling Machine For Super Capacitor Shell
TOB-CKK60M CNC belling machineis mainly suitable for super capacitor shell "V" shape flaring, convenient and end cover, gasket, insulation into the circle
Iron Nickel Foam
5mm Thickness Iron Nickel Foam
5mm Thickness Iron Nickel Foam For Battery Electrode Materials SPECIFICATIONS Model : TOB-IFeF-005 Material : Iron nickel foam, Sold in sheet. Dimension : 100*100*5mm, or customized as request Thickness : 5mm The aperture : 0.1mm-10mm (5-130ppi) Porosity : 75-98% Through Hole Rate : ≥98% Bulk density : 0.1-0.8g/cm3 Application field Exhaust gas purifier carrier materials,battery electrode materials, all kinds of catalyst carrier, especially for high temperature resistance and acid and alkali corrosion filtering material, the surface of the infrared burner materials, all kinds of industrial and civil heating material drying equipment, etc PACKAGE AND SHIPPING 1 Standard exported package : Internal bottle sealing, outside the aluminum-plastic composite membrane sealing 2 Shipping by express, by air, by sea according to customer's requirements to suggest the most suitable shipping mode SERVICES 1 We supply machines with battery technology support. 2 We can also supply a full set of materials for lithium battery including polymer battery, cylinder battery, mobile phone battery, EV battery. 3 We can also supply a full set of lithium battery equipment for lab research, pilot scale research and production line. 4 We can also supply a full set of battery technology for battery design, research and producing. We cooperated with each other, and we will do TOP OF THE BEST battery  Email : tob.amy@tobmachine.com  Skype : amywangbest86  Whatsapp/Phone number : +86 181 2071 5609
mini muffle furnace
1000 Degree Muffle Furnace
The TOB-KBF1100 Modelmini muffle furnaceadoptselectric Resistance wireas heating element, using double shell structure and 40 program temperature control system, electric phase-shifting trigger, thyristor control, furnace chamber using polycrystal alumina fiber material, double layer between the furnace shell is equipped with air cooling system, to rise and down temperature quickly. (Up to 1000℃ within 20mins)
Warm Isostatic Press
Warm Isostatic Press Machine
Warm isostatic press machine with up to 660 MPa pressure and 150°C temperature, designed for solid-state battery R&D, electrolyte densification, and pilot-scale processing.
Lanthanum Strontium Manganite
Lanthanum Strontium Manganite LSM Powder for Plasma Spraying
The LSM powder is the most used on the cathode side of the interconnect by plasma spraying.