Brand:
TOB NEW ENERGYitem no.:
TOB-GB1220-N-Sorder(moq):
1Payment:
L/C, T/Tproduct origin:
ChinaGlove Box Integrated H₂S Removal for Lithium-Sulfur and Solid-State Battery Research
Technical indicators
Water and oxygen content<1PPM
Leakage rate<0.001%vol/h
Product Overview
The TOB-GB1220-N-S glove box is a single-station, specifically designed for solid-state battery research and sulfide-based lithium-sulfur battery material systems, where strict environmental control and toxic gas management are essential.
The system integrates a single-column purification unit, PLC control with touchscreen interface, vacuum system, and a dedicated hydrogen sulfide (H₂S) removal device, forming a fully enclosed inert atmosphere workspace. The enclosure features an inclined operating surface and a removable safety glass front window, ensuring ergonomic operation and safety.
Under standard conditions (20°C, 1 atm, 99.999% inert gas), the system maintains ultra-low moisture and oxygen levels (<1 ppm), providing a stable environment for highly sensitive materials.
Application Focus: Sulfide System & Solid-State Battery
Sulfide-based solid electrolytes are extremely sensitive to moisture and can release H₂S gas when exposed to air. This system is specifically engineered to address these challenges:
● Integrated H₂S removal unit connected to the main circulation pipeline
● Ultra-low H₂O/O₂ control (≤1 ppm capability)
● Fully sealed circulation system to prevent contamination
● Controlled material transfer via electromagnetic valve-driven antechambers
It is particularly suitable for:
● Sulfide solid electrolyte synthesis
● Solid-state battery assembly
● Air-sensitive material handling
● Advanced battery laboratory environments
Glove Box Functional System
● Inert Gas Closed-Loop Circulation
The internal inert gas is continuously circulated through a purification system using a high-performance fan. During circulation, moisture and oxygen are continuously removed to maintain a stable ultra-clean environment.
● Automatic Regeneration System
The purification materials (molecular sieve and copper catalyst) can be regenerated. The regeneration process is fully controlled by the PLC system, ensuring consistent performance over time.
● Automatic Purging System
Atmosphere replacement inside the glove box is achieved through automatically controlled purge valves, ensuring rapid and efficient gas exchange.
● Pressure Control System
The internal pressure is automatically controlled by PLC. The working pressure can be freely set within ±15 mbar, and the system provides automatic protection when exceeding ±16 mbar.
● Vacuum Pump Control
The vacuum pump operates automatically based on system demand and can also be manually controlled.
Technical Specifications
| Item | Parameter | |
| Main parameter | Water/ oxygen index: Less than 1ppm | |
| Leakage rate : 0.001vol%/h | ||
| Glove box | Box | Box size: (L*W*H)=1220×750×900mm |
| Box material: stainless steel 304, thickness 3mm | ||
| Inner surface: stainless steel wire drawing treatment | ||
| Outside surface: paint, white | ||
| Front window | Tilt windows, transparent tempered safety glass, thickness 8 mmThe glass window adopts a solid O-ring (vacuum sealing method) flange window structure. | |
| Glove ports | The material is polyoxymethylene, O-ring seal, self-lubricating performance, easy to maintain, and good sealing performance | |
| Gloves | Butyl rubber, thickness 0.4mm, diameter 8", length 32" | |
| Filter: | 0.3 microns, a gas inlet and a gas outlet | |
| Shelf | Stainless steel, 2-3Layers | |
| Lighting | LED lights, installed in front of each glass window | |
| Connector | Standby interface 4pcs, DN 40 KF, Power interface 1pc (220V) | |
| Bigger antechamber | Chamber | Size: diameter 360mm, length 600mm |
| Material: 304 stainless steel | ||
| Surface: inner surface wire drawing process, outer surface painting (white) | ||
| Accessory | Sliding tray: 304 stainless steel | |
| Door: double door, anodized aluminum material, thickness 10mm, vertical operation, with lifting mechanism | ||
| Pressure gauge: Digital display | ||
| Control | The solenoid valve is automatically operated via a touch screen, and the supplementary gas is used as the working gas for the glove box | |
| Smaller antechamber | Chamber | Size: diameter 150mm, length 300mm (100mm length into the glove box) |
| Material: 304 stainless steel | ||
| Surface: inner: wire drawing process, outer: painting (white) | ||
| Accessory | Standard configuration: small cabin tray | |
| Door: double door, thread lock | ||
| Pressure gauge: Digital display | ||
| Control | The solenoid valve is automatically operated via a touch screen, and he supplementary gas is used as the working gas for the glove box | |
| Gas purification circulation system | Purification column | Function: gas sealed, remove water, remove oxygen |
| Container material: 304 stainless steel | ||
| Purification materials: copper catalyst: 5kg, molecular sieve: 5 kg | ||
| Purification capacity: oxygen: 60L, water: 2Kg | ||
| Water and oxygen indicators: less than 1ppm | ||
| Circulatory system | Working gas: nitrogen, argon, helium | |
| Recycling capacity: integrated fan flow 90m³ / h, install frequency conversion | ||
| Regeneration | Operation: PLC automatically controls the regeneration process Regeneration gas: working gas mixed with hydrogen gas, (hydrogen -10%) | |
| Vacuum pump | 12m³ / h, rotary vane pump, with oil mist filter, air vibration control | |
| Valves | Main valve: DN 40 KF, electrically operated angle valve | |
| Control valve: electromagnetic integrated valve | ||
| Control System | Function | Including self-diagnosis, power-off self-starting characteristics, with pressure control and adaptive function |
| Automatic control, cycle control, password protection | ||
| Pressure control | PLC Auto control, cabinet working pressure +/- 15mbar can be set freely, beyond +/- 16mbar system automatic protection | |
| Pedal | Control the box pressure, easy to operate boost and buck | |
| Display system | Using Siemens PLC touch screen, display running status, box pressure, system records etc | |
| Vacuum system control | Vacuum pump, can be manually or through the PLC to start, flow 12m³/h, vacuum of the transition chamber, and keep the box pressure balance, vacuum pump limit vacuum ≤ 2x10-1pa | |
| Basic components | Water analyzer | Measuring range: 0~500ppm platinum electrode structure (P2O5 structure, can reach the factory level by simple cleaning), a wide range of applications, especially for users such as lithium battery manufacturing and metal organic, can be restored to the initial state through the cleaning and regeneration process, avoiding one-time pollution and scrapping The problem. |
| Oxygen analyzer | Measuring range: 0 ~ 1000ppm | |
| The use of ZrO2 sensor, to avoid the fuel cell life is short, and avoid the problem of it can not be exposed in the air | ||
| Hydrogen sulfide removal unit | Dimensions: Diameter 238mm, Height 407mm. Material: 3mm thick 304 stainless steel, filled with high-efficiency active adsorption material. It is connected to the main circulation pipeline, allowing the circulating gas to first pass through the adsorber, primarily adsorbing the volatilized hydrogen sulfide gas. The adsorption material can be quickly and easily replaced. After replacing the material, the adsorption column can be evacuated to remove air and prevent contamination of the high-purity atmosphere inside the chamber. | |
Installation Requirements
| Item | Requirement |
| Inert Gas Cylinders | 2 × 99.99% (Ar/N₂/He) |
| High Purity Gas | 1 × 99.999% |
| Regeneration Gas | 1 × H₂mixture (5–10%) |
| Gas Consistency | All gases must be same base gas |
| Pressure Regulator (Working Gas) | >15 MPa / 0–1 MPa output |
| Pressure Regulator (Regeneration Gas) | >15 MPa / 0–0.5 MPa |
| Power Supply | 220V, 1.2 kW |
Acceptance Standard
Under standard conditions (20°C, 1 atm, 99.999% inert gas, empty chamber operation):
● Moisture level: <1 ppm
● Oxygen level: <1 ppm
Safety Notice (Critical for Sulfide Systems)
For sulfide material applications, strict safety procedures must be :
● Before opening the antechamber or main chamber, working gas must be fully replenished
● The atmosphere must be properly purged before exposure
● Failure to do so may result in H₂S leakage, which is hazardous
● Regular inspection and replacement of H₂S adsorption materials is required
Product Display